0 items
Asset Type
Unit Preference
C 3-stage reciprocating Boil-off-gas (BOG) compressor system maximum allowed rod. Load 100kN, rated discharge pressure of final stage 69 barg, suction pressure 1st stage 0.05 bar @ 30 degrees C, 2nd stage 4.6 bar @ 45 degrees C, 3rd stage 27.7 bar @ 45 degrees C, discharge pressure 1st stage 4.7 bar @ 176 degrees C, 2nd stage 27.9 bar @ 190 degrees C, 3rd stage 69 bar @ 160 degrees C, driven by a 250kw, 3/50/400 volt, 594 rpm ATEX 1022 EExd II B T4Loher motor, (1) 550 liter stainless steel vertical pulsation dampner vessel, manufactured by Nadoba Stabilini, serial #954, pressure 0.05 bar @ -118/+30 degrees C, 610mm diameter x 1740mm straight side, weld dished top and bottom, (1) 125 liter carbon steel horizontal pulsation dampner, manufactured by Tlakova Nadoba Stabilini, serial #955, pressure 10.7/69.6 bar @ 57/159 degrees C, weld dished ends, (1) carbon steel tube and shell horizontal 1st stage intercooler, manufactured by APL Apparatebau AG, serial #W8227/EC22601, tubeside pressure 10 barg @ -10/200 degrees C (27 liter), shell 10 barg @ -10/200 degrees C (53 liter), (1) carbon steel tube and shell horizontal 2nd stage intercooler, manufactured by APL Apparatebau AG, serial #W8228/EC22602, tubeside pressure 29 barg @ -10/200 degrees C (20 liter), shell 10 barg @ -10/200 degrees C (55 liter), (1) carbon steel tube and shell horizontal 3rd stage intercooler, manufactured by APL Apparatebau AG, serial #W8229/EC22603, tubeside pressure 78 barg @ -10/200 degrees C (9 liter), shell 10 barg @ -10/200 degrees C (42 liter), system also includes interconnecting pipework, valves, etc, ALL CE MARKED
pressure compressor cooling medium R717 Motor current: 144A
Ammonia Compressor C/T 20571. Inlet Casing Design Pressure 2500 PSIG, Outlet Casing Design Pressure 2500 PSIG; Outlet casing Design Temperature 450 Degrees F 1sr Critical speed 5300 RPM, Maximum Operating Temperature 380 Degrees F; Test Inlet Pressure 3750 PSIG; Test Discharge Pressure 3750 PSIG. NOTE: Used in train with turbines #206300 & 206301, and Compressor # 206303
115 to 125 max. psi Rotary Screw Air Compressor Oil Free, packaged design, with microprocessor controls, cooler and lubricator
Wet Gas Compressor Radial Split case two stage compressor motor through a Lufin gear reducer
The Datum compressor is an 18 frame size(inside case diameter) with a radial split case, six impellers and a back to back rotor design. The machine features a lube skid that supports the compressor, motor and gear, a gas skid for the double Dry Gas seals, and instrumentation for vibration and temperature detection.
MMSCFD Dry: 49.73; Lbs/Hr Wet: 224,820;
Inlet PSIA: 20.9; Inlet Temp: 106 Degree F; Inlet ACFM Wet: 24,183
Designed for Outdoor Use, Under roof.
All Electricals are Class 1, Group CD, Division 2.
Speeds: Maximum Continuous 5,653 RPM,
Trip Speed 5,719,
CCW rotation from drive end. With one piece shaft.
Motor, Gear reducer, and Compressor skid mounted.
Lufkin Gear reducer, 3.178:1 ratio, rated 10,300 HP.
The Oil control system is by Cobey, and skid mounted.
The Seal gas system and skid are by Flowserve.
IP55 motor, water cooled, with integrated air dryer, mounted in an acoustic cabinet,
with seven impellers. This is the low stage compressor that is part of a two stage system, designed to compress methanol, but can be used for other gas. The casing design pressure for the inlet is 700 psi and the outlet is 700 psi. The casing design temperature at the discharge is 500 degrees F, and the maximum operating temperature is 380 degrees F. The hydrostatic test pressure on both the inlet and discharge are 1050 psi. The first critical speed is 3750 RPM., The maximum continuous speed is 10,908 RPM. Nozzle orientation is up.(vertical) The compressor is base mounted along with the second stage compressor (IPP # 210368) and shares a common shaft. The entire compression train is designed to be driven by a steam turbine. See IPP stock # 210371.
Flow rate: 910 Nm3/hr 100/165 deg C Hydrogen 3-stage V-type compressor system aspiration flow 1010 m3/hr suction pressure stage 1 = 1/1.1 bar @ 20-40 deg C, stage 2 = 3.6 bar @ 140 deg C, stage 3 = 10.76 bar @ 40 deg C, pressure side stage 1 = 3.8 bar @ 165 deg C, stage 2 = 10.8 bar @ 160 deg C, stage 3 = 17 bar @ 100 deg C, ambient temperature -20/+10 deg C, water cooled compressor, performance 134kw 1500 rpm motor (missing) system also includes heat exchanger (gas cooler), pulsation dampers, separators, pipework, pressure gauges etc
oil free air Compressor packaged design
Air end compressor head Part # 1616 6551 GA55 GBD- part # 2901-0844-00.
- Variable speed motor based on load.
air cooled oil free rotary screw compressor This is a twin shaft screw compressor, positive displacement type 55 psia @ 60 degrees F outlet pressure The compressor is a type WQ 40-12/55, 1.2 kg/cu M, 20 degrees C, 75 cuM/minute 321 amps General Electric Energy Saver AC motor The intake flange is 8" and discharge flange is 6" and both are mounted at the top of the machine, and the instrumentation for monitoring the unit are mounted on the side as a panel. This unit is mounted in complete sound proof enclosure.
Gas compressor. Rated suction pressure 0.30 amps.. Rotation Drive end CCW
no ex proof System included (2) separator tanks (1) separate 4 cm³/U oil pump, type KF1/4 D10K POA ODD1 with 0.56 kW, 220-380, 50 Hz, 1.380 rpm electrical motor (1) separate control panel
air cooled rotary screw compressor oil free This is a twin shaft screw compressor This is a twin shaft 55 psia @ 60 degrees F outlet pressure The compressor is a type WQ 40-12/55, 1.2 kg/cu M, 20 degrees C, 75 cuM/minute General Electric Extra Severe Duty AC motor The intake flange is 8" and discharge flange is 6" and both are mounted at the top of the machine, and the instrumentation for monitoring the unit are mounted on the side as a panel. This unit is mounted in complete sound proof enclosure.
Ingersol Rand Centac Air compressor Centrifugal compressor 3/60/230/480 volt Serial # 157414 With R P Adams air cooler, 10" diameter x 12' long, 66 sq.ft surface area
T-30 Air Compressor belt driven by a Baldor Industrial motor The T-30 compressors are designed for reliability and ease of maintenance.
T-30 Air Compressor belt driven by a Baldor Industrial motor T-30 compressors are designed for reliability and ease of maintenance.
lubricated rotary screw Electronic controls. Air cooled. With disconnect and IR Variable speed drive,
rotary screw single stage air compressor With a 120 gallon receiver. with air cooling The compressor is belt driven The skid has analog controls.
low pressure hydrogen compressor, vertical,two stage. V-belts Hydrogen humidity 100% compressor, capacity 65 kW, suction pressure, 1 stage 1.05 bar,30 C; 2nd stage 3,0 bar/34 C; discharge pressure abs 1 st stage 3.2 bar/145 C; 2nd stage 7.1 bar/122 C. 1st stage cylinder dia 370mm; 2nd stage 220mm. Cylinder material Ni-resist. Safety valve on 1st stage react at 3.5 bar; on 2nd stage 7.5 bar. Cooling water 5 cbm inlet temp 24 C@3 bar.
two stage compressor SO # 60.5-7315
driven by 220/253kW, 3/50-60/400/440-460 volt, 1463/1750-1759 rpm motor, with model DE235 HP refrigerant air dryer, manufactured by M.T.A,spa, serial #2200077950, 3/50/400 volt, IP22, R134a refrigerant, pressure 22.6 bar LP side, 26 bar HP side,