Type: Boiler
Subtype: Steam
Manufacturer: Cleaver Brooks
Model: CB200-730-150
Condition: Used
Material: Carbon Steel
Boiler Type: Water Tube
Capacity (Design): 11,340 kg/h (25,000 lb/h)
Fuel Type: Natural Gas. Pressure: 10.3 bar (150 psi). Burner Manufacturer: Cleaver Brooks.
Type: Boiler
Subtype: Steam
Manufacturer: Burnham
Model: LN3L-150-50-G-BNM
Condition: Used
Material: Carbon Steel
Boiler Type: Firetube
Power: 111.9 kW (150 HP)
three pass fire tube boiler 5021 MBH MBH input 6278 Fireside heating surface area is 750 sq.ft Firing rate is as follows: 1000 BTU Gas (MBH) =6277, 140,000 BTU/Gal. Oil (GPH) =44.8 Safety valve rated for 6000 psi Boiler has 182, two inch tubes This boiler features FGR and low Nox operation with it's IRI gas train While firing natural gas, emmissions levels are are no greater than 30 PPM of NO x This boiler features 3 gas passes that extract the maximum usable heat from the fuel while maintaining optimum flow for forced draft firing It also has easy opening/closing doors that minimize labor and parts cost’s while performing routine maintenance such as cleaning and inspections Water requirements are 6551 pounds of water or 785 gallons Approximate weight wet is 16,251 lbs., approximate dry weight is 9,700 lbs
Capacity (Design): 2,347 kg/h (5,175 lb/h). Fuel Type: Natural Gas. Pressure: 1.03 bar (15 psi). Low NOx: Yes.
Type: Boiler
Subtype: Steam
Manufacturer: Burnham
Model: LN3L-150-50-G-BNM
Condition: Used
Material: Carbon Steel
Boiler Type: Firetube
Power: 111.9 kW (150 HP)
three pass fire tube boiler 5021 MBH MBH input 6278 Fireside heating surface area is 750 sq.ft Firing rate is as follows: 1000 BTU Gas (MBH) =6277, 140,000 BTU/Gal. Oil (GPH) =44.8 Safety valve rated for 6000 psi. Boiler has 182, two inch tubes This boiler features FGR and low Nox operation with it's IRI gas train While firing natural gas, emmissions levels are are no greater than 30 PPM of NO x This boiler features 3 gas passes that extract the maximum usable heat from the fuel while maintaining optimum flow for forced draft firing It also has easy opening/closing doors that minimize labor and parts cost’s while performing routine maintenance such as cleaning and inspections Water requirements are 6551 pounds of water or 785 gallons. Approximate weight wet is 16,251 lbs., approximate dry weight is 9,700 lbs.
Capacity (Design): 2,347 kg/h (5,175 lb/h). Fuel Type: Natural Gas. Pressure: 1.03 bar (15 psi). Low NOx: Yes.
Type: Boiler
Subtype: Steam
Manufacturer: Ansaldo Volund
Condition: Used
Material: Carbon Steel
Boiler Type: Water Tube
Power: 13,100 kW (17,567 HP)
and gas oil fired energy input 13.1 MW fuel input natural gas 1206 kg/hr, gas oil 1097 kg/hr, air flow 14,000 Nm3/hr, flue gas flow natural gas 14,150 Nm3/hr, gas oil 14,866 Nm3/hr, heating surface area furnace 60sqm, screen 2.6sqm, evaporator 33sqm, walls of convection part 25sqm, economizer 1 683sqm, economizer 2 78 SqM, total 881 SqM. 2 x 20 t/hr boilers working in tandem, the boilers are all welded water tube boiler with natural water circulation, built as a vertical and self-contained construction in which the downcomers form the supporting columns, vertical expansion of the boiler is free upwards, boiler has a radiation part, a convection part and a detached economizer, the radiation part is to reduce the flue gas temperature before the convection part, the radiation part is built as an all-welded membrane wall section on the sides, top and partition wall, the economizer is in the back of the convection part and is made with horizontal tube coils, these are a nest of pipes consisting of 14-tube lines of each 28 tubes, the evaporator is made with diagonal tube coils, which are a nest of 6-tube lines of each 28 tubes, the detached economizer is built as a four sided casing tower in which are placed horizontal convection heating surfaces, final condensing (Ceecon) economiser which preheats the boiler feed water. Main item consists of: (2) 20 t/hr (design load, 100% Maximum Continuous Rating) Ansaldo Volund water tube boilers, design pressure 91 bara, normal working pressure 83 bara, feed water temperature 105 deg C, flue gas for dimensioning 16,667 Nm3/hr, flue gas temperature after economizer 139.5 deg C, content of CO2 in flue gas 8.92 volume %, H20 15.84 volume %, O2 2.07 volume %, net calorific value 42.8 MJ/kg (gas oil), 39 MJ/kg (natural gas), Saacke type TSAAYD-135-E3-6275 steam atomizing burner, designed for natural gas or oil, heat input 22,000kg/hr, gas oil output 190-1329 kg/hr, natural gas 163-1631 Nm3/hr, (1) 1640ltr c/steel boiler drum, steam space load 275 m3/m3xh, 1200mm diameter x 3m long, 40mm thick, weld dished ends, (1) Detached in-line fin tube Economizer, manufactured by Emvertec, 683sqm, design pressure 13.5 bar, (1) 316 s/steel Deaerator vessel, manufactured by Cool Technology ltd, design pressure 2 bara @ 105 deg C, operating pressure 0.21 bara (3) Feed water pumps, manufactured by KSB, type HGM-2/15, Other associated equipment include fans, valves, pumps, instruments, control panels, platform between boilers, etc
Capacity (Design): 40,370 kg/h (89,000 lb/h). Fuel Type: Natural Gas. Pressure: 80 bar (1,160 psi). Temperature: 297 °C (566.6 °F). Controls: Yes. Burner Manufacturer: Saacke. Deaerator System: Yes.