Brazed Aluminum Heat Exchanger (BAHX) - Designed for Cryogenic Air Separation- New/Unused from a cancelled project.
5 Process Streams:
Stream A: 513 psig (35.4 barg) @ 150 deg. F (65 deg. C) max, -320 deg. F (-196 deg. C) min, Volume 16.1 cu. ft (0.46 cu. m.)
Stream B: 190 psig (13.1 barg) @ 150 deg. F (65 deg. C) max, -320 deg. F (-196 deg. C) min, Volume 35.1 cu. ft. (1 cu. m.)
Stream C: 190 psig (13.1 barg) @ 150 deg. F (65 deg. C) max, -320 deg. F (-196 deg. C) min, Volume 62.6 cu. ft. (1.77 cu. m.)
Stream D: 1028 psig (70.9 barg) @ 150 deg. F (65 deg. C) max, -320 deg. F (-196 deg. C) min, Volume 46.9 cu. ft. (1.32 cu. m.)
Stream E: 190 psig (13.1 barg) @ 150 deg. F (65 deg. C) max, -320 deg. F (-196 deg. C) min, Volume 8.9 cu. ft. (0.25 cu. m.)
Material of Construction: 5083 Aluminum