Overview
Heat Exchanger
Block
Ralph Coidan LTD.
BD 30S
Used
Graphite
Capacity
2.6 m² (28 ft²)
Dimensions
Horizontal
Shell
8 bar (116 psi)
185 °C (365 °F)
Carbon Steel
Other Specifications
Yes
Graphite
6 bar (87 psi)
Graphite
185 °C (365 °F)
  • carbon block Hykarb heat exchanger,
  • design pressure process side: 6 bar + full vacuum @ -29/185 degrees C
  • service side 8 bar + full vacuum @ -29/185 degrees C
  • 20 liter capacity
  • design code: ASME VIII DIV 1
  • PED CAT I Gas group 1
  • CE0040

Similar Equipment

Graphite Ralph Coidan BD 30S Block Heat Exchanger

Type: Heat Exchanger

Subtype: Block

Manufacturer: Ralph Coidan LTD.

Model: BD 30S

Condition: Refurbished/Rebuilt

Material: Graphite

Heat Transfer Surface Area: 2.7 m² (29.1 ft²)

Shell Pressure: 8 bar (116 psi)

asset #10005706, design code: ASME VIII DIV 1 PED CAT 1 gas group 1, CE0040

Shell Temperature: 185 °C (365 °F). Vacuum: Yes. Process Pressure: 6 bar (87 psi). Process Temperature: 185 °C (365 °F).

Graphite Ralph Coidan BD20 Block Heat Exchanger

Type: Heat Exchanger

Subtype: Block

Manufacturer: Ralph Coidan LTD.

Model: BD20

Condition: Used

Material: Graphite

Heat Transfer Surface Area: 1.86 m² (20 ft²)

Shell Pressure: 5.2 bar (75.4 psi)

Shell Temperature: 200 °C (392 °F). Vacuum: Yes. Process Pressure: 5.2 bar (75.4 psi). Process Temperature: 200 °C (392 °F).

Graphite Ralph Coidan Block Heat Exchanger

Type: Heat Exchanger

Subtype: Block

Manufacturer: Ralph Coidan LTD.

Condition: Used

Material: Graphite

Nozzle Schedule: openings 2-150mm, 2-100mm

Ralph Coidan CYH-H55 Block Heat Exchanger

Type: Heat Exchanger

Subtype: Block

Manufacturer: Ralph Coidan LTD.

Model: CYH-H55

Condition: Used

Material: Graphite

Heat Transfer Surface Area: 10 m² (107.6 ft²)

Orientation: Horizontal

Hykarb carbon cubic block cross flow heat Exchanger design pressure process side 7.8 barg @ 0/160 degrees C service side 15 barg @ 0/160 degrees C operating pressure process side 5.2 barg + full vacuum @ -0.185 degrees C service side 10 barg @ 2.417 degrees C 24 pass on process side, 10 pass on service side, unit made from (4) carbon HP2/20 block elements, 536mm block length

Shell Pressure: 10 bar (145 psi). Shell Temperature: 160 °C (320 °F). Nozzle Schedule: openings: process side 2- 50mm, service side 2-50mm. Process Pressure: 5.2 bar (75.4 psi). Process Temperature: 160 °C (320 °F).