double effect evaporation system. See video of system operating at http://www.youtube.com/watch?v=Y6J52r-maPE. Capacity based on a brine stream at 24% to 50% strength. Feedstock of 32,000 lbs/hr(normal operating) or up to 50,000 lbs./hr. brine at ~ 20-25% NaBr is sent to the first effect, where it is strengthened to ~ 35% NaBr. The steam generated from this effect is used for heating on the second effect. Final target for brine leaving the second effect is 45-50% NaBr. The first effect (IPP Stock # 216077) (drum type)t is 2,000 gallon, and is manufactured by Paget. With a 400 sq.ft. "U" tube heater, this unit is operaing at 310 degrees F using 150# steam. The second effect is a modular, forced circulation system, designed by Swenson and manufactured by Four Corp. This effect is operating at atmospheric pressure and using the steam generated from the first effect to heat the second effect 838 sq. ft shell and tube heater(reboiler, IPP Stock # 216082). Overheads are condensed (IPP Stock # 216085). Product at ~ 50% NaBr is sent to storage. Circulation is acheived by a Goulds 6,000 gpm centrifugal pump. The first effect is a stand alone unit, the second effect is a modular system with all equipment mounted with in it's own framework. Instrumentation by Rosemount.
Built in Economizer.
3-pass wet back furnace tube deisgn and oil fired, Manufacturer: Hamworthy Combustion, Type: SG5/1900 automatic gas fuel, boiler has an economiser, design pressure 110psig, deisgn code BS2790:1989, class 1, (2) feed water pumps, total weight= 7625kg
normal working pressure 83 bara, flue gas for dimensioning 16,667 Nm3/hr, flue gas temperature after economizer 139.5 deg C, content of CO2 in flue gas 8.92 volume %, H20 15.84 volume %, O2 2.07 volume %, net calorific value 42.8 MJ/kg (gas oil), 39 MJ/kg (natural gas), Saacke type TSAAYD-135-E3-6275 steam atomizing burner, designed for natural gas or gas oil, heat input 22,000kg/hr, gas oil output 190-1329 kg/hr, natural gas 163-1631 Nm3/hr, energy input 13.1 MW, fuel input natural gas 1206 kg/hr, gas oil 1097 kg/hr, air flow 14,000 Nm3/hr, flue gas flow natural gas 14,150 Nm3/hr, gas oil 14,866 Nm3/hr, heating surface area furnace 60sqm, screen 2.6sqm, evaporator 33sqm, walls of convection part 25sqm, economizer 1 683sqm, economizer 2 78sqm, total 881sqm the boiler is an all welded water tube boiler with natural water circulation, built as a vertical and self-contained construction in which the downcomers form the supporting columns, vertical expansion of the boiler is free upwards, boiler has a radiation part, a convection part and a detached economizer, the radiation part is to reduce the flue gas temperature before the convection part, the radiation part is built as an all-welded membrane wall section on the sides, top and partition wall, the economizer is in the back of the convection part and is made with horizontal tube coils, these are a nest of pipes consisting of 14-tube lines of each 28 tubes, the evaporator is made with diagonal tube coils, which are a nest of 6-tube lines of each 28 tubes, the detached economizer is built as a four sided casing tower in which are placed horizontal convection heating surfaces, boiler includes: (1) 1640ltr c/steel boiler drum, steam space load 275 m3/m3xh, 1200mm diameter x 3m long, 40mm thick, weld dished ends, (1) Detached in-line fin tube Economizer, manufactured by Emvertec, 683sqm, design pressure 13.5 bar, (1) 316 s/steel Deaerator vessel, manufactured by Cool Technology ltd, design pressure 2 bara @ 105 deg C, operating pressure 0.21 bara (3) Feed water pumps, manufactured by KSB, type HGM-2/15, Other associated equipment include fans, valves, pumps, instruments, control panels, etc
Bepex Torus Disc Cooler
U shaped trough, continuous design.
Certified by Moorhead Machinery & Boiler Co
Moorhead Serial number 605-2300.
Shell rated 15 psi @ 350 degrees. No jacket on trough.
U shaped trough, bolted flat top, with one end bolted for rotor removal. Inside dimensions 48” ID x 9’ long
Nominal 106 cubic foot working capacity, approx.
Unit has a tubular rotor with hollow discs mounted on the rotor to allow heating/cooling media to flow through the rotor. The shaft is mounted on outboard bearings, rotary joint on one end, packing glands. Chain and sprocket drive with a gear reducer and 25 HP 3/60/230/460 volt motor. 15 RPM shaft speed.
The residence time is adjustable by and overflow weir at the discharge end.
electronic intermittent pilot ignition Surface heating area, 83.4 Sq. Ft. Gas connection is 1.25", water inlet and outlet are 2", and pressure relief line is 1" Flue size is 12".
Electric hot oil heater Heat output: 1,229,194 BTU/hr Complete system with (2) vertical 180 KW electric heaters, 3/60/480 volt, Serial Number J600-1 & 2 circulating pumps
single effect vertical falling film evaporator jacket -1/6 bar @ 200 degrees C (1100 liter), 6.7 m3/hour evaporation rate Fabrik #3981 single pass tubeside, 316Ti (1.4571) stainless steel tubesheets, 800mm diameter 316Ti stainless steel shell with expansion joint, 7m overall length, (2) 316Ti stainless steel (1.4571) dished heads evaporator with (1) 316Ti stainless steel (1.4571) expansion boiler, 1227 liter, 800mm diameter x 2250mm, pressure and vacuum resistant, manual valves and control valves
single effect falling film evaporator pressure internal -1/6 bar @ 200 degrees C (1291 liter), jacket -1/6 bar @ 200 degrees C (1020 liter) 9.4 m3/hour evaporation rate single pass tubeside, 316Ti (1.4571) stainless steel tubesheets, 700mm diameter 316Ti stainless steel (1.4571) shell with expansion joint, 7250mm overall length, (1) 316Ti stainless steel (1.4571) dished head, (1) 316Ti stainless steel (1.4571) bonnet head evaporator with (1) 316Ti stainless steel (1.4571) expansion boiler, 1227 liter, 800mm diameter x 2250mm, pressure and vacuum resistant, manual valves and control valves
single effect evaporator 100 psi @ 350 degrees F in the jacket on the bottom 1/3 of straight side of tank only. 2097 liters.
This boiler can fire on Natural Gas or Light Oil , however, in the previous application they were only burning gas, so there are no accessories to burn the light oil. 04/25/24 Per Miller & Chitty Manufacturer weight is 36,000 LBS. (RP)
Spraymaster Dearator 14 GPM Total Boiler HP 203
gas fired combined heat and power system, system includes: 5000 kg/hr Cochran single pass waste heat recovery boiler, max continuous 5010kg/hr, serial #95/2766, manufactured by Cochran Boilers Limited,design pressure 13 barg, inlet temperature 430 degrees C, design saturated steam temperature 188 degrees C (@ 10.5 barg), safety valve setting 11.55 barg, heat transfer duty 2934 +- 15%, specific garavity/density 0.95 kg/m3, specific heat 1.00 kCal/kg.C, approximate boiler dimensions 2630mm diameter x 6m long, boiler an with economiser, manufactured by Flametec ltd, serial #35690/04068, design pressure 20 barg @ 160 degrees C, 2 x 3360.8 Kw (4201 kVA) gas engine driven electrical generator, engine manufactured by Waukesha (Dresser), model #16VAT27GL, serial #C-80859/1 & C-80859/2, SAA #2000-168, natural gas fired, continuous, comp ratio 9/1, min.WKI 91, ignition timing (BTDC) 11-02, service 4650 HP (3469 Kw), altitude limit 500 feet (152 meter), governed speed 1000 rpm, 0.80mm valve intake & exhaust clearance, firing order 1R-1L-4R-4L-7R-7L-6R-6L-8R-8L-5R-5L-2R-2L-3R-3L, AC generator (alternator) manufactured by Leroy Somer, type LSA-56-BM65-6P, serial #167056-2, IP 23, 3360.8 Kw, 4201 kVA power rating, 11000 volt, 220.5 Amp, 3 phase, 50 Hz, 1000 rpm, excitation AREP, all mounted on a carbon steel skid oil lubrication, cooling water system, MCC control panels, some ductwork, process description: natural gas is used to fuel two gas engine powered generator sets that provide electrical power to the site, with the ability to export surplus power to the grid, heat extraction from the exhaust gases is used within the heat recovery system to heat the boiler feed water to the steam boiler, which provides steam to the plant steam main, excess heat from each engines jacket water cooling system and intercooler cooling system is removed and dispersed to atmosphere by the heat dump radiators, the intercooler cooling system is used to provide cooling to the engine lubricating oil system, valves are provided on the jacket water cooling, and lubricating oil systems to enable future connections to a second heat recovery system
kettle type reboiler With SS U-tube bundle
Repaired by Alfonso Serial Number 9138-86 (3) reinforcing rings around straight side of tank
Elliott steam turbine generator set with Elliott turbines
Single stage back pressure style units
We believe this unit only has 100 hours runtime since overhaul.
Engine, gearbox and generator are mounted in a common skid.
The Elliott gearbox reduces the turbine speed of 5750 RPM to a final speed of 1800 RPM to drive a conventional 4-pole, 2-bearing alternator rated 1000kW/1176kVA with 0.85 PF, 163 Amps and wound for 2400/4160V/3/60 Hz service.
Rated Power - 1350HP/1007kW; Rated Turbine Speed - 5750 RPM; Rated Inlet Steam Pressure - Gauge - 599 PSI; Rated Steam Temperature - 750 Deg F; Rated Exhaust Pressure - 155 PSI.
Gear Drive is a model # C4 R4, Serial # B102145C-G1, Rated power 1350, Service factor 1.66, High speed shaft;5750, Low speed shaft;1815 , Tag # 802654 C4 2624.
Alternater is built by BBC (Brown Boveri) Serial # C36-A076-102, Drive end bearing 6322/C3, opposite drive end bearing 6320/C3. Time rated continuous; Frame # 717, enclosure is drip proof; rated ambient temp. 40 degrees C.
With twin Amtek oil coolers and 1.5 hp oil pump.
The package includes generator control and synch panels with scope, no boilers with units.
Electric hot Oil Heater CAT Number COSW-6508-200SCRCAXX, 480 Volt, 3 Phase, 60 Cycle, 120 volt 606 Cycle controls. Electric heating elements, and control panel (4) zone heat with on/off Switch for each zone.
kettle type reboiler U tube bundle is 12" diameter x 16' 11" straight side. 403 " long total length around the bend (1) CS bolted dished head for tube bundle Carbon Steel Kettle type re-boiler shell 280" over all length. Tube Type: U-Tube. Tube Number: 22. Tube Diameter: 1 in. Tube Length: 203 in. Tube Thickness: 0.08 in. Nozzle Schedule: Openings: Tube side - (1) 3" inlet, (1) 1" outlet; Shell side - (1) 6" inlet, (1) 8" vapor outlet, (1) 2" liquid outlet.