back pressure turbine. steam consumption 13.55 lb/BHP/hr, Total flow 148200 lbs/hr.
Type: Turbine
Subtype: Steam
Manufacturer: Siemens
Model: HG40
Condition: Used
Power: 10,200 kW (13,678 HP)
Speed (RPM): 5660
back pressure turbine, steam consumption 13.55 lb/BHP/hr, inlet temp normal 940 deg F, inlet temp max 965 deg F, Total flow 148200 lbs/hr.
Inlet Pressure: 127.6 bar (1,850 psi). Inlet Temperature: 518.3 °C (965 °F). Outlet Pressure: 14.1 bar (205 psi). Outlet Temperature: 248.9 °C (480 °F).
Type: Turbine
Subtype: Steam
Manufacturer: Siemens
Model: EG-400-2
Condition: Unused
Power: 8,457 kW (11,341 HP)
Speed (RPM): 6076-7975
Single cylinder extraction backpressure of Axial flow type, extraction steam 205 psi (14.2 bar),Steam consumption 130 ton/hr.
Inlet Pressure: 40.7 bar (590 psi). Inlet Temperature: 385 °C (725 °F). Outlet Pressure: 6.4 bar (93 psi). Extraction?: Yes. Extraction Points: 1. Extraction Details: Single cylinder extraction at 205psi.. Backpressure?: Yes.
Type: Turbine
Subtype: Steam
Manufacturer: Siemens
Model: K1100
Condition: Unused
Power: 6,808 kW (9,130 HP)
Speed (RPM): 4230
condensing turbine. inlet pressure normal 190 psig steam consumption 9.9 lb/BHP/hr, Total flow 83000 lbs/hr.
Inlet Pressure: 14.5 bar (210 psi). Inlet Temperature: 248.9 °C (480 °F). Outlet Pressure: 0.12 bar (1.7 psi). Outlet Temperature: 210 °C (410 °F). Condensing?: Yes.