SAA #2000-168, natural gas fired, continuous, comp ratio 9/1, min.WKI 91, ignition timing (BTDC) 11-02, service 4650 HP (3469 Kw), altitude limit 500 feet (152 meter), governed speed 1000 rpm, 0.80mm valve intake & exhaust clearance, firing order 1R-1L-4R-4L-7R-7L-6R-6L-8R-8L-5R-5L-2R-2L-3R-3L, AC generator (alternator) manufactured by Leroy Somer, type LSA-56-BM65-6P, serial #167056-2, IP 23, 3360.8 Kw, 4201 kVA power rating, 11000 volt, 220.5 Amp, 3 phase, 50 Hz, 1000 rpm, excitation AREP, all mounted on a carbon steel skid.