Type: Turbine
Subtype: Steam
Manufacturer: Dresser Rand
Model: E-1SU2B1504
Condition: Unused
Material: Carbon Steel
Power: 2,051 kW (2,750 HP)
Speed (RPM): 6540-6760
Steam turbine originally designed to be used to drive a compressor, but can be used to drive other machines.
Dresser Rand Series ET-186, Five Rateau stages. Normal speed is 6540 rpm, max. speed is 6760 rpm. First critical speed is 2900 rpm, second critical speed is 7800 rpm. Speed regulation is by a Woodward governor, model 505E.
The turbine has the following alarms/shutdowns; Over speed, Emergency valve, solenoid valve, Low oil pressure, and high input steam pressure.
Requires 63 gpm cooling water for oil cooler. Complete pressurized oil system operating at 116 psig. Size of turbine alone is 9’ x 6’ x 7’ at 14,000 lbs.
Inlet Pressure: 62.7 bar (910 psi). Inlet Temperature: 470 °C (878 °F). Outlet Pressure: 4.1 bar (59.7 psi). Outlet Temperature: 250 °C (482 °F). Stages: 5.
Type: Turbine
Subtype: Steam
Manufacturer: Worthington
Model: 3TDFOV2
Condition: Used
Material: Carbon Steel
Power: 7,308 kW (9,800 HP)
Speed (RPM): 5650
multi stage Rotation is clock wise. 5 stage Rateau
Inlet Pressure: 37.2 bar (540 psi). Inlet Temperature: 371.1 °C (700 °F). Outlet Pressure: 0.14 bar (1.96 psi). Outlet Temperature: 53.3 °C (128 °F). Condensing?: Yes. Stages: 5.
Type: Turbine
Subtype: Steam
Manufacturer: Siemens
Model: EG-400-2
Condition: Unused
Material: Carbon Steel
Power: 8,457 kW (11,341 HP)
Speed (RPM): 6076-7975
Single cylinder extraction backpressure of Axial flow type, extraction steam 205 psi (14.2 bar),Steam consumption 130 ton/hr.
Inlet Pressure: 40.7 bar (590 psi). Inlet Temperature: 385 °C (725 °F). Inlet Steam Flow: 267.6 kg/h (590 lb/h). Outlet Pressure: 6.4 bar (93 psi). Extraction?: Yes. Extraction Points: 1. Extraction Details: Single cylinder extraction at 205psi.. Backpressure?: Yes. Stages: single.
Type: Turbine
Subtype: Steam
Manufacturer: Terry
Model: F26-10R
Condition: Refurbished/Rebuilt
Power: 10,158 kW (13,622 HP)
Speed (RPM): 6300
101,000 lbs./hr. at 600 psig, 750 degrees F., 2.5 in HGA. Electronic governor with direct actuation manufactured by Woodword. Base mounted on a common plate with a Tacke, With 600 gallon lube oil supply system, mechanical drive by a 10 hp AC motor Back up oil lube is by a 1.5 hp, DC electric motor Part of 10MW Ideal Generator IPP #212617.
Inlet Pressure: 41.4 bar (600 psi). Inlet Temperature: 398.9 °C (750 °F). Inlet Steam Flow: 45,813 kg/h (101,000 lb/h). Outlet Pressure: 0.91 bar (13.3 psi). Outlet Temperature: 46.7 °C (116 °F). Extraction?: Yes. Extraction Details: Capable of 15psi (nominal) extraction between 6th & 7th stages..
Used turbines remain a core component of industrial energy systems, converting thermal or fluid energy into mechanical motion or electrical power. Whether you’re looking to support a cogeneration system, back up steam recovery, or replace a failed driver, IPP provides inspected, in-stock turbine systems from 20 global plant sites. With over 47 years of experience, IPP is the world’s largest supplier of used process equipment, with more than 15,000 systems in stock — including steam turbines, gas turbines, and mechanical drives.
IPP’s inventory includes backpressure turbines, condensing turbines, and mechanical drive turbines from trusted OEMs such as GE, Dresser-Rand, Siemens, Elliott, and Peter Brotherhood.
Learn more about how turbines are used in process industries via Power Engineering.