Type: Turbine
Subtype: Steam
Manufacturer: Dresser Rand
Model: E-1SU2B1504
Condition: Unused
Material: Carbon Steel
Power: 2,051 kW (2,750 HP)
Speed (RPM): 6540-6760
Steam turbine originally designed to be used to drive a compressor, but can be used to drive other machines.
Dresser Rand Series ET-186, Five Rateau stages. Normal speed is 6540 rpm, max. speed is 6760 rpm. First critical speed is 2900 rpm, second critical speed is 7800 rpm. Speed regulation is by a Woodward governor, model 505E.
The turbine has the following alarms/shutdowns; Over speed, Emergency valve, solenoid valve, Low oil pressure, and high input steam pressure.
Requires 63 gpm cooling water for oil cooler. Complete pressurized oil system operating at 116 psig. Size of turbine alone is 9’ x 6’ x 7’ at 14,000 lbs.
Inlet Pressure: 62.7 bar (910 psi). Inlet Temperature: 470 °C (878 °F). Outlet Pressure: 4.1 bar (59.7 psi). Outlet Temperature: 250 °C (482 °F). Stages: 5.
Type: Turbine
Subtype: Steam
Manufacturer: Turbodyne
Model: U-22575
Condition: Used
Power: 8,572 kW (11,495 HP)
Speed (RPM): 12863
multi valve single row, solid rotor Casing is manufactured from a Chrome Molly Alloy, with a forged Shaft. "Engineering solution" Single stage Special 13,506 rpm, rated 1150 psi steam @ 890 deg F, 550 psi exhaust Includes spare rotor and parts
Inlet Pressure: 79.3 bar (1,150 psi). Inlet Temperature: 476.7 °C (890 °F). Outlet Pressure: 37.9 bar (550 psi). Backpressure?: Yes. Stages: 1.
Type: Turbine
Subtype: Steam
Manufacturer: Dresser Rand
Model: ET-5
Condition: Used
Material: Carbon Steel
Power: 2,804 kW (3,760 HP)
Speed (RPM): 6309-6760
Inlet Pressure: 27.4 bar (398 psi). Inlet Temperature: 380 °C (716 °F). Outlet Pressure: 0.15 bar (2.1 psi). Outlet Temperature: 60 °C (140 °F). Condensing?: Yes. Stages: 5.
Type: Turbine
Subtype: Steam
Manufacturer: Siemens
Model: HG32
Condition: Unused
Power: 6,234 kW (8,360 HP)
Speed (RPM): 9615
back pressure turbine. steam consumption 13.2 lb/BHP/hr, Total flow 106900 lbs/hr.
Inlet Pressure: 127.6 bar (1,850 psi). Inlet Temperature: 518.3 °C (965 °F). Outlet Pressure: 14.1 bar (205 psi). Outlet Temperature: 248.9 °C (480 °F). Backpressure?: Yes.
Used turbines remain a core component of industrial energy systems, converting thermal or fluid energy into mechanical motion or electrical power. Whether you’re looking to support a cogeneration system, back up steam recovery, or replace a failed driver, IPP provides inspected, in-stock turbine systems from 20 global plant sites. With over 47 years of experience, IPP is the world’s largest supplier of used process equipment, with more than 15,000 systems in stock — including steam turbines, gas turbines, and mechanical drives.
IPP’s inventory includes backpressure turbines, condensing turbines, and mechanical drive turbines from trusted OEMs such as GE, Dresser-Rand, Siemens, Elliott, and Peter Brotherhood.
Learn more about how turbines are used in process industries via Power Engineering.