Showing 3 of 3 matching Gasification Plants.
Tail Gas Treatment Unit Available Separately from a 3,000 Metric Ton/Day Clean Syngas Refinery Gasification Plant for Sale IPP Stock #600759
-
This unit was installed in 2000 as part of a gasification facility to convert heavy refinery residues into clean syngas. The facility shut down in early 2013. The entire gasification facility is available for sale.
-
The unit was designed by ABB Lummus Global and utilizes Parsons technology for the removal of approximately 2.2% of hydrogen sulfide (H2S) and sulfur dioxide (SO2) from 11,000 kg/hr of tailgas leaving the Sulfur Recovery Unit (SRU) section which is also available for purchase. The MDEA flow rates in the contactor and regeneration sections are 100 m3/hr.
-
To View More Details on this Unit, Please Click on the Link Below:
Tailgas Treatment Unit Brochure
(2) Texaco/GE Gasifiers
Down-Flow, Quench Type
-
Previously part of a gasification system used in refinery gasification
-
Specifications:
-
2.8 M (9.2') dia. x 10.2 M (33.5') Inconel 825/CS
-
1,000 PSI @ 800 degrees Fahrenheit (69 bar @ 430 degrees Celsius)
-
59 Metric Ton/Hr (1,400 Metric Ton/Day) of heavy refinery residue feedstock
-
130 Metric Ton/Hr (3,000 Metric Ton/Day) of clean syngas
-
Included with these gasifiers:
-
(2) 3.2 M (10.5') dia. x 7.9 M (25.9') 316LSS/CS scrubbers
-
(2) 36 CBM/Hr @ 99 bar Uraca feed pumps
-
(10) Monel Oxygen double-block-and-bleed valves
-
Monel Oxygen piping
-
These Texaco/GE gasifiers utilize quench technology because:
-
best choice for gasifying feedstocks such as refinery residues that have a high metal concentration
-
proven success record in the refinery industry
-
reliability and simplicity of operation
-
offers superior environmental benefits
This Gasification Unit is Available Separately from a 3,000 Metric Ton/Day Clean Syngas Refinery Gasification Plant for Sale IPP Stock #600759
Gas Cooling Unit Available Separately from a 3,000 Metric Ton/Day Clean Syngas Refinery Gasification Plant for Sale IPP Stock #600759
Gas Cooling Unit: Energy is recovered in this unit by generation of 20 bar, 15 bar and 6 bar steam. Carbonyl sulfide hydrolysis reactors included. Technology by ABB Lumus Global.