Polymer filter continous rotary filtration system1220 SqCm active screen area9500 Cm/Hr capacity, 48000 watt oil/vapor heating capacity, with 2 heater zones. CS construction.RexRoth 11 KW power pack 3/50/500 volt 1460 Rpm. 2900 Kg Filter
plastic 'Utiliser' dry granulator
model 20-strand
321 stainless steel rotor with cutting blades
motor : 50/60 Hz, 400/380/415 volt, 981/982/1184 rpm , IE2 CE motor
aluminium chamber with hinged top inspection cover
diverter valve and screen changer masch #20004017,2- 110 cm2 screens screen dimensions 120mm x 0.5mm x 93mm (+0.5),230-600 kg/hr throughput, heating capacity of the 6-cartirdges is 6 x 1000 watt, Gebhard/HLP type cartridges, hydraulically driven by a Heusinger and Salmon powerpack, powerpack driven by a 11/12.7 kw,3/50/60/380/660/420/720/380/660/480/830 volt,1440/1465/1730/1755 rpm 2-speed motor, local control panel on a davit,
type 20-48T
Plastic 'Utiliser' dry granulator
Model 20-strand
321 stainless steel rotor with cutting blade
Aluminium chamber with hinged top inspection cover
driven by 15 kw, 3 phase, 50/60 Hz, 400/380/415/460/660/690 volt, 970/975/1180 rpm
plastic 'Utiliser' dry granulator
model 20-strand
321 stainless steel rotor with cutting blades
motor : 50/60 Hz, 380/400/415/460/660/690 volt, 970/975/1180 rpm
aluminium chamber with hinged top inspection cover
centrifugal dryer, for plastic pellets/granules
rated 6500 Kg/H product throughput, 50 CuM/H water rate, approx 2,550 NM3/h
30" Industrial dishwasher, 304 SS, with dual baskets
Washing chamber is 30" x 30" x 36". Pump driven by a 2 HP motor.
Inlet is 3/4", discharge is 1.5"
Waters 2695 alliance HPLC with 2487 detector. The 2487 dual wavelength absorption detector features the following: Advanced programmability, Unmatched signal to noise ratio, reduced optical band with and exceptional linearity. The Waters 2695 separations module is used for In-vitro diagnostic testing to analyze many different compounds. This is an integrated solvent and sample management platform.
Waters 2695 alliance HPLC with 2487 detector. The 2487 dual wavelength absorption detector features the following: Advanced programmability, Unmatched signal to noise ratio, reduced optical band with and exceptional linearity. The Waters 2695 separations module is used for In-vitro diagnostic testing to analyze many different compounds. This is an integrated solvent and sample management platform.
The Husky INQ400 PET is a high-output, multi-material injection molding system specifically engineered for producing PET bottle preforms from virgin PET homopolymer, regrind, or barrier-layer materials. The system integrates a 64-cavity rotary turret mold with a robust clamp mechanism, high-capacity plasticizing/injection section, and an operator-friendly control platform.
Supports the rotary 64-cavity turret mold used for PET preform manufacture.
Incorporates:
Provides precise mold alignment and repeatable movement across each molding cycle.
Integrated control system uses an PC-based platform.
Standard interface includes:
Provides adjustments for process parameters, diagnostics, alarms, recipes, and machine sequencing.
Waters 2695 alliance HPLC with 2487 detector. The 2487 dual wavelength absorption detector features the following: Advanced programmability, Unmatched signal to noise ratio, reduced optical band with and exceptional linearity. The Waters 2695 separations module is used for In-vitro diagnostic testing to analyze many different compounds. This is an integrated solvent and sample management platform.
Waters 2695 alliance HPLC with 2487 detector. The 2487 dual wavelength absorption detector features the following: Advanced programmability, Unmatched signal to noise ratio, reduced optical band with and exceptional linearity. The Waters 2695 separations module is used for In-vitro diagnostic testing to analyze many different compounds. This is an integrated solvent and sample management platform.
lab pelletizer
7" wide opening
stainless steel fluid bed crystallizer
used on PET pellets with heated nitrogen
total pressure drop, ca.30 mbar, differential pressure ca 2 mbar, design pressure pe=90 mbar
product thickness ca.200mm
approximate bed with glass inspection hatches
1.6m wide x 3.3m long x 500mm deep with glass inspection hatches
Openings include: product inlet 100mm diameter with rotary valve, hot air inlet 700mm diameter, hot air outlet 700mm diameter, product outlet 150mm x 185mm, chamber with hood,
Pfaudler Thermal fluid (oil) loop system, all mounted inside a cabinet with pressure gauges, system consists of (1) HMD Magnetic drive centrifugal pump, manufactured by HMD Sealless Pumps Ltd, driven by 5.5 kw, 3/50/415 volt, 2900 rpm motor, (1) 60 liter electric heated tank, manufactured by Pfaudler Balfour, serial #500019, design pressure 10 barg @ 20/200 degrees C, electric heater manufactured by Heatex Ltd, serial #991433, 50kw, 3 phase, 415 volt, EEx d 11C T3, (2) stainless steel plate and shell heat exchangers, manufactured by Vahterus Oy, type PSHE-3HH80/1/1-HE-101 & PSHE-3HH60/1/1-HE-100, serial #6532 & #6531, design pressure on both sides 25 bar @ 200 degrees C, (1) 325 liter horizontal header tank, manufactured by Pfaudler-Balfour, serial #500019, design pressure 10 barg @ 20/200 degrees C, (1) 20 liter vertical tank, manufactured by Pfaudler-Balfour, serial #500019, design pressure 10 barg @ 20/200 degrees C, all items insulated
Unused Hydraulic unit for a 3V Cogiem filter dryer.3.7kw, 200 bar max pressure. 150 liter tank. Complete except Motor.