Used heat exchangers for sale: efficient thermal transfer systems for heating, cooling and energy recovery
Highest-ranked available inventory for this selection.
Used heat exchangers for sale: efficient thermal transfer systems for heating, cooling and energy recovery
Choose a subtype for a more focused set of listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Use this setting to include or exclude equipment with this feature.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Enter a keyword to match this specification.
Set a numeric threshold to narrow the matching listings.
Set a numeric threshold to narrow the matching listings.
Select one or more values to narrow the current listings.
Set a numeric threshold to narrow the matching listings.
Enter a keyword to match this specification.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Set a numeric threshold to narrow the matching listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Set a numeric threshold to narrow the matching listings.
Set a numeric threshold to narrow the matching listings.
Enter a keyword to match this specification.
Set a numeric threshold to narrow the matching listings.
Enter a keyword to match this specification.
Set a numeric threshold to narrow the matching listings.
Enter a keyword to match this specification.
Use this setting to include or exclude equipment with this feature.
Set a numeric threshold to narrow the matching listings.
Set a numeric threshold to narrow the matching listings.
Select one or more values to narrow the current listings.
Select one or more values to narrow the current listings.
Enter a keyword to match this specification.
Set a numeric threshold to narrow the matching listings.
Set a numeric threshold to narrow the matching listings.
Showing 25 of 1068 matching Heat Exchangers.
tube pressure rated by -1/10bar @-10/200 degrees C (volume 66 liter), shell pressure rated by -1/10bar @ -10/200 degrees C (volume 180 liter). Tubes alpha silicon carbide. Length: 4,800 mm. Shell-side Passes: 1. Tube-side Passes: 1. Tube Type: Straight Tube. Tube Number: 121. Tube Diameter: 14 mm. Tube Length: 4,200 mm. Tube Thickness: 1.5 mm. Nozzle Schedule: shell side: (1) DN100, (2) DN200, (1) DN300; tube side: (1) DN150, (1) DN200. Capacity: 246 L. Heat Exchanger Tube Capacity: 66 L.
Process sidde rated 45 PSI @ -30/+122 degrees F. Service side rated 30 PSI @ -30/+122 degrees F.
side A = 550 ltr, side B = 570ltr
pressure both sides -1/10 bar @ -50/150 degrees C (18 liter/17 liter) fully insulated, CE-0036,
Rated FV/300 psi @ -20 to 425 degrees tube side; FV/50 psi @ -20 to 425 degrees F shell side.
with glass lined clamped heads Tube Number: 18. Tube Diameter: 0.75 in. Tube Length: 216 in.
2-stage (2) 450 Sq Ft condensers bolted together, end to end, with same configuration and material in both stages, Upper stage and lower stage each have a 316LSS shell, CS heads. Shell is 0.135" thick, Heads are 1.12" thick CS. Spiral Material: Stainless Steel 316.
AL6XN channel heads with R-Stamp(1994) Tube Diameter: 1.25 in. Tube Length: 144 in. Tube Thickness: 0.02 in. Nozzle Schedule: - Nozzle Schedule: - Two 32" tube side nozzles (brine inlet & outlet) - One 18" steam inlet - One 4" condensate outlet - One 3" drain - Two 1" drain/vents.
(2) 300mm high cone sections,
Heads are CS faced with 316 L SS Spiral Material: Stainless Steel 316L.
cubic block heat exchanger process side is 2-pass with (2160) slots, 9.5mm x 3mm,service side is multi-stage with (756) 9.5mm diameter tubescan be used vertical or horizontal.
FAILED HYDROTEST- FOR PARTS OR REBUILDING
multi-pass tubeside (2) c/steel dished heads Shell-side Passes: 1. Tube Number: 104. Tube Diameter: 19 mm. Tube Length: 2,400 mm. Nozzle Schedule: Head openings: - Tubeside: (1) head with 2-4", (1) head with 2-1/2" - Shell side: 1-4", 2-1 1/2", 1-1", 2-1/2".
Tantalum lined carbon steel tube sheets TUV APPROVED Pressure tube side -1/4 bar @ 170 degrees C (volume 122 liter), pressure shell side 4 bar @ -17/40 degrees C (volume 225 liter) Expansion joint manufactured by DeDietrich, serial number 27031, internal pressure rated -1/4 bar @ 170 degrees C (volume 67 liter), openings (1) DN80 and (1) DN150, second head: manufactured by DeDietrich, serial number 27030, internal pressure rated -1/4 bar @ 170 degrees C (volume 82 liter), openings (1) DN80 and (1) DN250 Tube Type: Straight Tube. Tube Number: 179. Tube Diameter: 19.5 mm. Tube Length: 2,600 mm. Nozzle Schedule: - Openings: (1) DN40, (2) DN100, (1) DN150.
Additional features: expansion bellow, (2) carbon steel channel heads, Tube-side Passes: 4. Tube Number: 122. Tube Diameter: 25 mm. Tube Length: 2,500 mm. Tube Thickness: 2 mm. Nozzle Schedule: openings tubeside - 2-75mm, 4-6mm, shell - 2-300mm, 1-75mm, 1-20mm.
and two 1" vent/drains Tube Type: Straight Tube. Tube Number: 168. Tube Diameter: 0.75 in. Tube Length: 48 in. Tube Thickness: 0.01 in. Nozzle Schedule: shell side has two 4" nozzles, Bottom Bonnet has two 3" nozzles, top has one 8" nozzle.
TEMA type BEM Length: 95 in. Tube Type: Straight Tube. Tube Number: 76. Tube Diameter: 0.75 in. Tube Length: 95 in. Tube Thickness: 0.06 in. Nozzle Schedule: - Nozzles: Two 8" nozzles, Two 2" nozzles, One 4" vent, Two 0.75" drains .
Tantalum clad heads 18" diameter x 75.25" Overall length. (face to face 48") Length: 75.3 in. Tube Type: Straight Tube. Tube Number: 168. Tube Diameter: 0.7 in. Tube Length: 48 in. Tube Thickness: 0.015 in. Nozzle Schedule: Shell side - two 4", Tube side - one 8" and two 3"..
Internals are 25 Ra electropolished. External as welded and passivated Inner and outer tube sheets are removable hell inlet and outlets are 8" RFSO flange, Tube inlet/outlet are 3" WE. Two 3/4" couplings for the vents & drain. Length: 88 in. Shell-side Passes: 4. Tube-side Passes: 4. Tube Type: U-Tube. Tube Number: 172. Tube Diameter: 0.5 in. Tube Length: 84 in. Tube Thickness: 0.04 in.
(1) 316 stainless steel bonnet head, Tube Type: U-Tube. Tube Number: 22. Tube Diameter: 20 mm. Tube Length: 2,500 mm. Tube Thickness: 2 mm. Nozzle Schedule: openings tube side: 2-50mm, shell side: 1-80mm, 2-25mm.
Used heat exchangers are essential in virtually every industrial setting where fluids need to be heated or cooled efficiently. These systems transfer thermal energy between liquids, gases, or steam without mixing the media—making them critical in process optimization, energy recovery and environmental control. With over 47 years of experience, IPP supplies used, secondhand and surplus heat exchangers from 20 global plant sites and maintains a massive inventory of 15,000+ systems ready for fast shipment.
IPP offers a wide variety of heat exchanger types including shell and tube, plate, air-cooled, spiral, and double-pipe designs from trusted brands like Alfa Laval, API Schmidt-Bretten, Tranter, Graham and ITT Standard.
Heat exchangers are unfired heat transfer equipment used in process plants. Heat exchangers are used for the transfer of heat or cold between two fluids for the purpose of heating the process, cooling the process, or condensing vapors during the process. Heat exchangers are measured in Square Feet. There are several different types of heat exchangers. These include:
Heat exchangers must withstand temperature, pressure and chemical exposure:
Learn more about industrial heat exchanger design and selection from Chemical Processing.
Search the IPP inventory or contact IPP’s thermal systems experts to find the right used, surplus or secondhand heat exchanger for your facility. From simple replacements to full energy recovery systems, IPP helps you optimize performance while cutting lead times and costs.
Have questions about Heat Exchangers or our services? Learn more about our products and why customers choose IPP.